Show simple item record

dc.contributor.authorAl Hashimi, Husain
dc.contributor.authorHammer, Caleb F.
dc.contributor.authorLebon, Michel T.
dc.contributor.authorZhang, Dan
dc.contributor.authorKim, Jungho
dc.date.accessioned2019-02-28T11:00:22Z
dc.date.available2019-02-28T11:00:22Z
dc.date.copyright11/21/2017 12:00:00 AM
dc.date.issued2018
dc.identifier.issn0022-1481
dc.identifier.otherht_140_03_031601.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4251640
dc.description.abstractTechniques based on temperature-sensitive paints (TSP) to measure time-resolved temperature and heat transfer distributions at the interface between a wall and fluid during pool and flow boiling are described. The paints are excited using ultraviolet (UV) light emitting diodes (LEDs), and changes in fluorescence intensity are used to infer local temperature differences across a thin insulator from which heat flux distribution is obtained. Advantages over infrared (IR) thermometry include the ability to use substrates that are opaque to IR (e.g., glass, plexiglass and plastic films), use of low-cost optical cameras, no self-emission from substrates to complicate data interpretation, high speed, and high spatial resolution. TSP-based methods to measure wall heat transfer distributions are validated and then demonstrated for pool and flow boiling.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titlePhase-Change Heat Transfer Measurements Using Temperature-Sensitive Paints
dc.typeJournal Paper
dc.journal.volume140
dc.journal.issue3
dc.journal.titleJournal of Heat Transfer
dc.identifier.doi10.1115/1.4038135
dc.journal.fristpage31601
dc.journal.lastpage031601-15
dc.treeJournal of Heat Transfer:;2018:;volume( 140 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record