dc.description.abstractThe paper presents the method of fouling degree evaluation of the heating surfaces in pulverized coal-fired boiler during coal combustion and biomass co-combustion. The fouling processes have a negative impact on the boiler operation by reducing the steam outlet temperature, increasing the mass flow rate of cooling spray water, and may be the reason for overheating of the superheater (SH) tube material. This leads to a reduction of the boiler efficiency and can cause shortening of a lifetime as well as damage of boiler heat exchangers, in particular, the steam SH. The basis of fouling degree assessment method are the dimensionless coefficients, which represent current values of heat absorbed by an individual heat exchanger in comparison to the value for a clean surface. The coefficients are determined based on the calculated heat power of individual heat exchanger taking into account the adjustment resulting from the flue gas temperature inside a combustion chamber. The results of the analysis showed a significant reduction of the amount of heat absorbed by the convection SH during continuous boiler operation. The next important conclusion is a large increase of the heat amount transferred to the radiant SH, which may result in exceeding the permissible temperature of the tube material. The proposed method together with on-line monitoring system installed on the boiler is used to calculate the fouling degree of individual heating surfaces. Accurate monitoring of boiler heating surface conditions can be used to optimize soot blowers operation and finally to improve process efficiency.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleAnalysis of Fouling Degree of Individual Heating Surfaces in a Pulverized Coal Fired Boiler
dc.typeJournal Paper
dc.journal.volume140
dc.journal.issue3
dc.journal.titleJournal of Energy Resources Technology
dc.identifier.doi10.1115/1.4037936
dc.journal.fristpage32003
dc.journal.lastpage032003-8
dc.treeJournal of Energy Resources Technology:;2018:;volume 140:;issue 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record