Shock Tube Demonstration of Acousto-Optically Modulated Quantum Cascade Laser as a Broadband, Time-Resolved Combustion Diagnostic
View/ Open
Date
2018Author
Loparo, Zachary E.
Muraviev, Andrey V.
Figueiredo, Pedro
Lyakh, Arkadiy
Peale, Robert E.
Ahmed, Kareem
Vasu, Subith S.
Metadata
Show full item recordAbstract
We provide the first demonstration of an acousto-optically modulated quantum cascade laser (AOM QCL) system as a diagnostic for combustion by measuring nitric oxide (NO), a highly regulated emission produced in gas turbines. The system provides time-resolved broadband spectral measurements of the present gas species via a single line of sight measurement, offering advantages over widely used narrowband absorption spectroscopy (e.g., the potential for simultaneous multispecies measurements using a single laser) and considerably faster (>15 kHz rates and potentially up to MHz) than sampling techniques, which employ fourier transform infrared (FTIR) or GC/MS. The developed AOM QCL system yields fast tunable output covering a spectral range of 1725–1930 cm−1 with a linewidth of 10–15 cm−1. For the demonstration experiment, the AOM QCL system has been used to obtain time-resolved spectral measurements of NO formation during the shock heating of mixture of a 10% nitrous oxide (N2O) in a balance of argon over a temperature range of 1245–2517 K and a pressure range of 3.6–5.8 atm. Results were in good agreement with chemical kinetic simulations. The system shows revolutionary promise for making simultaneous time-resolved measurements of multiple species concentrations and temperature with a single line of sight measurement.