Show simple item record

dc.contributor.authorChang Shuenn-Yih
dc.date.accessioned2019-02-26T07:57:07Z
dc.date.available2019-02-26T07:57:07Z
dc.date.issued2018
dc.identifier.other%28ASCE%29EM.1943-7889.0001401.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250487
dc.description.abstractAn unusual overshooting behavior might be experienced in the forced response of a high-frequency mode for a structure-dependent integration method. This unusual overshooting is different from that found in the free vibration response and can be detected by examining an alternative form of the local truncation error derived from a forced vibration response rather than a free vibration response. In addition, this local truncation error can be applied to develop an effective remedy to remove the adverse overshoot behavior. This remedy can be obtained by introducing a load-dependent term into the difference equation for displacement increment for structure-dependent integration methods, such as the first and second Chang family methods. All the analytical findings are numerically verified.
dc.publisherAmerican Society of Civil Engineers
dc.titleElimination of Overshoot in Forced Vibration Responses for Chang Explicit Family Methods
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue2
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)EM.1943-7889.0001401
dc.page4017177
dc.treeJournal of Engineering Mechanics:;2018:;Volume ( 144 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record