Show simple item record

dc.contributor.authorKhan Easa;Lobo John A.;Linzell Daniel G.
dc.date.accessioned2019-02-26T07:55:03Z
dc.date.available2019-02-26T07:55:03Z
dc.date.issued2018
dc.identifier.other%28ASCE%29BE.1943-5592.0001236.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250263
dc.description.abstractA recently constructed and commissioned in-service light rail transit bridge in Denver, Colorado was examined analytically and via field testing to study its live load performance. The bridge is a four-span horizontally curved structure, composed of chorded prestressed concrete bulb tee girders. The bridge was designed following the American Railway Engineering and Maintenance-of-Way Association (AREMA) guidelines from the Manual of Railway Engineering, which do not explicitly address transit rail structures. In-situ load testing and calibrated finite element analyses were conducted to study the live load performance and determine the effects of speed and centrifugal forces on dynamic amplification and live load distribution. Field-testing and model results indicated variations in live load distribution and amplification as train speed increased. In addition, live load distribution and amplification values differed from results determined using equations from AREMA and the AASHTO guidelines, documents that are commonly used to assist analysis and design due to a lack of available provisions tailored to transit rail bridges.
dc.publisherAmerican Society of Civil Engineers
dc.titleLive Load Distribution and Dynamic Amplification on a Curved Prestressed Concrete Transit Rail Bridge
dc.typeJournal Paper
dc.journal.volume23
dc.journal.issue6
dc.journal.titleJournal of Bridge Engineering
dc.identifier.doi10.1061/(ASCE)BE.1943-5592.0001236
dc.page4018029
dc.treeJournal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record