Show simple item record

dc.contributor.authorLima Gustavo Meirelles;Luvizotto Edevar;Brentan Bruno Melo;Ramos Helena M.
dc.date.accessioned2019-02-26T07:51:32Z
dc.date.available2019-02-26T07:51:32Z
dc.date.issued2018
dc.identifier.other%28ASCE%29WR.1943-5452.0000852.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4249875
dc.description.abstractOne of the primary concerns in water supply systems is pressure control. High pressure increases both leakage and the risk of pipes bursting, while low pressure can reduce the water supplied to consumers and allow the intrusion of pathogens. Therefore, the operation of the equipment must be optimized to avoid such problems. In high pressure zones, pressure reducing valves (PRVs) are commonly used for pressure control. However, the energy dissipated from head loss could be recovered to produce electrical energy. The use of pumps as turbines (PAT) in this case is an alternative to improve the system efficiency. However, owing to the dynamic operation, PAT performance drops significantly during some periods of the day. The use of variable speeds can solve this problem, but the PAT selection to optimize the operation remains an issue. Therefore, this paper presents a method to simultaneously select PATs and schedule their operation using variable speed to improve energy recovery and reduce leakage. Two networks are studied and the performance in leakage control is compared with the PRV operation.
dc.publisherAmerican Society of Civil Engineers
dc.titleLeakage Control and Energy Recovery Using Variable Speed Pumps as Turbines
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue1
dc.journal.titleJournal of Water Resources Planning and Management
dc.identifier.doi10.1061/(ASCE)WR.1943-5452.0000852
dc.page4017077
dc.treeJournal of Water Resources Planning and Management:;2018:;Volume ( 144 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record