• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Static Test and Seismic Dynamic Response of an Innovative 3D Seismic Isolation System

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002195.pdf (2.454Mb)
    Date
    2018
    Author
    Liu Wenguang;Xu Hao;He Wenfu;Yang Qiaorong
    Metadata
    Show full item record
    Abstract
    Seismic isolation is an efficient strategy to protect structures from the effects of moderate to severe earthquake shaking. Conventional isolation devices can reduce the structural response in horizontal directions only; however, three-dimensional (3D) ground motions have been observed in earthquake records. In this paper, an innovative 3D seismic isolator is proposed. A new kind of asymmetric oblique hysteretic model is illustrated, and a quasistatic compression test of a model device using three lead rubber bearings (LRBs) is conducted. The test results and theoretical model results match well. A significant asymmetric property is observed in the hysteretic curves. The proposed hysteretic model can efficiently simulate the vertical mechanical behavior of a 3D seismic isolation system. The effects of different parameters are highlighted based on the theoretical mechanical model. The inclination angle, friction coefficient, and second shape factor of the inclined LRBs strongly influence the vertical behavior of the proposed device. A dynamic response analysis of the substructure of a nuclear power plant (NPP) is conducted. The hysteretic curves have the shape of an asymmetric quadrangle; this shape is similar to that observed in the test results. The vertical acceleration response of the vertical isolation structure is reduced by 33% compared with that of a fixed-base structure and reduced by 58% compared with that of a horizontal isolation structure. The proposed 3D isolator can sufficiently isolate the seismic input.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4249479
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV