    Seismic Assessment of Existing Steel Chevron Braced Frames

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002037.pdf (3.532Mb)
    Date
    2018
    Author
    Balazadeh-Minouei Yasaman;Koboevic Sanda;Tremblay Robert
    Metadata
    Show full item record
    Abstract
    The seismic response of existing, nonductile 3- and 1-story steel chevron braced frames is examined to identify potential deficiencies. The structures are located on the west coast of Canada. They were designed in accordance with the 198 Canadian building code, without any specific seismic ductility considerations for braces, brace connections, or floor beams. The frame beams are light because they carry low tributary gravity loading. The evaluation was performed using the procedures of the Canadian building code and American standard. Response spectrum analysis and nonlinear time-history analysis (NLTHA) methods were conducted. Different numerical models were used for NLTHA to verify the effect of the nonlinear response of different components on seismic response. The evaluation using the Canadian building code required strengthening of all braces in both structures, whereas the braces were found to be acceptable by the American standard’s linear dynamic procedure (LDP). However, the American standard’s nonlinear dynamic procedure (NDP) revealed high inelastic demand in the upper and lower levels of the 1-story frame, in excess of the brace deformation capacities. From both LDP and NDP, beams are expected to fail by strong axis buckling prior to brace buckling, a behavior confirmed by detailed finite-element analysis. Linear dynamic procedure showed that columns are also deficient. Columns could not be assessed using NDP because of beam buckling occurring first in the analyses. For the 1-story frame with retrofitted beams, NDP showed the possibility of column buckling.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4249319
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV