Show simple item record

dc.contributor.authorKnox C. L.;Dizhur D.;Ingham J. M.
dc.date.accessioned2019-02-26T07:45:40Z
dc.date.available2019-02-26T07:45:40Z
dc.date.issued2018
dc.identifier.other%28ASCE%29ST.1943-541X.0002021.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4249164
dc.description.abstractThe testing program reported herein was designed to provide experimental results from a structure relevant to the type and form of unreinforced masonry (URM) buildings that are commonly found in several countries. The experimental test provided results associated with the system-level displacement-controlled quasistatic response of a half-scale two-story perforated URM wall loaded in-plane. The geometry of the wall was specifically chosen to investigate the effect of shallow spandrels on the multistory response. It was concluded that the response of the two-story perforated URM wall exhibited an approximate elastic–perfectly plastic behavior, with a nonlinear response. The external piers rocked over their interstory effective height and the wall reached an ultimate drift of 1.4% with minimal strength loss but with extensive damage to the top-level spandrel elements.
dc.publisherAmerican Society of Civil Engineers
dc.titleTwo-Story Perforated URM Wall Subjected to Cyclic In-Plane Loading
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue5
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0002021
dc.page4018037
dc.treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 005