• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Bond Durability of Carbon Fiber–Reinforced Polymer Tendons Embedded in High-Strength Concrete

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0000870.pdf (3.490Mb)
    Date
    2018
    Author
    Toumpanaki Eleni;Lees Janet M.;Terrasi Giovanni P.
    Metadata
    Show full item record
    Abstract
    The structural performance of carbon fiber–reinforced polymer (CFRP) pretensioned structures is controlled by the bond between the CFRP tendons and concrete. The bond strength of CFRP sand-coated tendons can be affected by humid environments due to the porous epoxy matrix structure or by defects in the external sand coating layer of CFRP tendons, e.g., due to storage conditions. Pullout tests were carried out to assess the bond strength performance of sand-coated tendons embedded in high-strength concrete and immersed in water at either 23 or 4°C. Sand-coated CFRP tendons with two different core diameters of either 4.2 or 5.4 mm were studied. To assess the effect of the sand coating coverage on the bond, half sand-coated and uncoated tendons were also tested. An image processing technique was developed to help correlate bond strength variations with variations in the sand coating. An average difference of 24% between the bond strengths of the half sand-coated and full sand-coated tendons was recorded. A large scatter in the pullout results for the sand-coated tendons of diameter 5.4 mm was observed and this was attributed to the manufacturing process. There was no clear trend of bond strength degradation in the sand-coated tendons even after roughly 1.5 years of full immersion in water irrespective of the exposure temperature. However, an increase in the bond strength of the uncoated tendons and in the bond stiffness of all CFRP tendons was observed. This was felt to be the result of concrete autogenous shrinkage in high-strength concrete and the potential swelling effects of the tendons in a humid concrete environment. Analytical models are used to describe the bond stress-slip behavior, and their suitability for sand-coated CFRP tendons is studied.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4248474
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV