• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Evaluation of Steel-Plate Composite Walls Subject to Blast Loads

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002163.pdf (1.527Mb)
    Date
    2018
    Author
    Bruhl Jakob C.;Varma Amit H.
    Metadata
    Show full item record
    Abstract
    Steel-plate composite (SC) walls consist of a concrete infill sandwiched between two steel faceplates. The faceplates are anchored to the concrete using stud anchors or ties, and connected to each other using steel tie bars. This type of sandwich composite construction has the potential for excellent blast resistance because the steel faceplates provide confinement to the concrete and prevent concrete scabbing and spalling. This paper presents the results of an experimental investigation conducted to evaluate the blast resistance of small-scale SC wall panel specimens by subjecting them to short-duration uniform pressure loads in a blast load simulator facility. All the panel specimens had the same global dimensions (length = 1,626 mm, width = 279 mm, and thickness = 12 mm) but varied certain design parameters: (1) the faceplate reinforcement ratio (ρ=2× faceplate thickness/wall thickness = 3.5–5.6%), (2) faceplate slenderness ratio (λ = stud anchor spacing/plate thickness = 18–29), (3) faceplate yield strength (Fy=4–7  MPa), and (4) tie reinforcement ratio (ρt = area of tie bar/square of tie spacing = .37–1.23%). The blast load peak reflected pressures varied from 13 to 425 kPa, and the corresponding reflected impulses varied from 1,79 to 7,65  kPa· ms. This paper summarizes the experimental results including (1) the dynamic displacement history at two locations, (2) acceleration history at midspan, and (3) strain histories at several locations on the steel faceplates. The reflected pressures were also recorded, and high-speed videography from three directions was used to record the response. Experimental results indicate that the structural responses of all 12 panel specimens included elastic and plastic deformations and were dominated by flexural behavior. Experimental results were compared with analytical results from a single-degree-of-freedom (SDOF) model. The SDOF model estimated displacements on average 1% larger than measured, indicating that one-way behavior of SC walls subjected to short-duration uniform pressure loads is reasonably estimated using fundamental bending mechanics.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4248044
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV