Show simple item record

dc.contributor.authorLi Zhixiang;Zhao Canhui;Deng Kailai;Wang Weian
dc.date.accessioned2019-02-26T07:34:47Z
dc.date.available2019-02-26T07:34:47Z
dc.date.issued2018
dc.identifier.other%28ASCE%29ST.1943-541X.0002152.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248032
dc.description.abstractPerfobond rib shear connectors (PBL shear connectors) are widely used in composite structures for their excellent mechanical performance. However, the mechanism responsible for the mechanical behavior of multihole PBL shear connectors has seldom been investigated. This study focuses on the load sharing and slip distribution in multiple holes of a PBL shear connector. The load–slip relationships and strain distributions of 14 different multihole PBL shear connector specimens are experimentally determined. The results reveal that the design parameters, i.e., the spacing and diameters of perforated rebar and the concrete strength, affect the load sharing and slip distribution. Based on the physical tests, an analytical model is proposed to describe the mechanical behavior of multihole PBL shear connectors, with the assumption of a Lorentzian distributed strain on the perforated steel plate and surrounding concrete. Further mathematical derivation is performed to determine the load sharing and slip distribution in multiple holes of a PBL shear connector. The accuracy of the theoretical solution is considered satisfactory compared with the physical tests.
dc.publisherAmerican Society of Civil Engineers
dc.titleLoad Sharing and Slip Distribution in Multiple Holes of a Perfobond Rib Shear Connector
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue9
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0002152
dc.page4018147
dc.treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record