dc.description.abstractA numerical study on the fire performance of bolted splice connections is presented. A finite element (FE) model, incorporating geometric and material nonlinearities, nonlinear contact interactions, and elevated temperature properties of steel was developed for undertaking fire response analyses. The model was validated by comparing its predictions with experimental data. To investigate the effect of critical factors on the behavior of beams and their bolted splice connections, parametric studies were performed using the validated model. Results from the parametric studies indicate that the gaps between link and stub beams, free length of flange splice plate, and thermal gradients developed during fire exposure have a significant effect on fire response of bolted splice connections. The beam fails when deflections exceed the limiting value specified in the current standard. Results also indicate that temperature gradients, lateral restraints, and levels of axial stiffness significantly influence the fire behavior of the beams in column-tree moment-resisting frames.
dc.publisherAmerican Society of Civil Engineers
dc.titleBehavior of Steel Column-Trees under Fire Conditions
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue9
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0002135
dc.page4018135
dc.treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record