Show simple item record

dc.contributor.authorPan Yuxin;Ventura Carlos E.;Liam Finn W. D.
dc.date.accessioned2019-02-26T07:34:19Z
dc.date.available2019-02-26T07:34:19Z
dc.date.issued2018
dc.identifier.other%28ASCE%29ST.1943-541X.0002104.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4247977
dc.description.abstractThis paper studies the effects of long duration ground motion on three conventional low-rise light-frame wood houses with different sheathing configurations. These are two-story residential houses built with an oriented strand board (OSB) wall system and stucco sheathing, an OSB wall system without stucco, and a horizontal board sheathing wall system without stucco. Three-dimensional numerical models of the structures were developed using the Timber3D program and calibrated with full-scale shake table test data. The shear wall systems were simulated with the modified Stewart (MSTEW) model that accounts for cyclic and in-cycle degradation. For this study, seven short duration ground motions from the China Lushan earthquake of 213 and seven long duration motions from the adjacent 28 Wenchuan earthquake were selected. Both suites of motions were recorded at the same strong motion stations and were spectrally matched to have similar spectra. Fragility curves for collapse and drift exceedance were derived based on incremental dynamic analysis (IDA). Results indicate that under long duration motions, median collapse capacities for the three houses are reduced by 26–61% compared to that due to short duration motions. A 1% lesser peak interstory drift (ISD) approaching collapse was also estimated under long duration motions. In addition, for a 3% design drift limit, there is a 17% higher probability of exceeding this drift due to long duration shaking. This study demonstrates that from the three types of houses analyzed in this study, house that had blocked shearwalls with OSB sheathing showed significantly higher seismic resistance than the other two housing types analyzed, while house that used horizontal wood boards showed the lowest resistance. Structures with horizontal board sheathing should not be permitted in areas of significant seismic activity.
dc.publisherAmerican Society of Civil Engineers
dc.titleEffects of Ground Motion Duration on the Seismic Performance and Collapse Rate of Light-Frame Wood Houses
dc.typeJournal Paper
dc.journal.volume144
dc.journal.issue8
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0002104
dc.page4018112
dc.treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 008
dc.contenttypeFulltext