• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Seismic Shear Forces in Post-Tensioned Hybrid Precast Concrete Walls

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0002079.pdf (770.5Kb)
    Date
    2018
    Author
    Buddika H. A. D. Samith;Wijeyewickrema Anil C.
    Metadata
    Show full item record
    Abstract
    A method to accurately calculate seismic shear forces in post-tensioned hybrid (PH) precast concrete walls under risk-targeted maximum considered earthquake (MCER) level ground motions is essential to avoid unexpected damage or possibly failure. Although extensive research on seismic performance evaluation of PH precast concrete walls has been carried out previously, the postelastic amplification of shear forces due to higher-mode effects, relative to the design shear forces computed using the equivalent lateral force (ELF) procedure, has been addressed only in a limited manner. In the present study, first the equations to calculate shear forces in PH precast concrete walls, post-tensioned rocking (PR) precast concrete walls, and reinforced concrete (RC) shear walls are examined and their limitations discussed. Then an extensive numerical study of PH precast concrete walls designed using the equivalent lateral force procedure is carried out. The applicability of currently available equations to calculate seismic base shear forces in PH precast concrete walls are evaluated by comparing them with the results of nonlinear response history analysis (NLRHA) using a suite of 4 ground motions. Next, the shear force distribution over the wall height in PH precast concrete walls is also investigated. Regarding the base shear force, it is found that the existing methods developed for PR precast concrete walls and RC shear walls can produce reasonable estimates of the base shear. In the case of the wall shear force along the height of the wall, existing methods for RC shear walls are found to provide good estimates. Based on the results obtained, (1) an equation to calculate the peak base shear force and (2) a multilinear shear force design envelope to calculate wall shear forces along the height of the PH precast concrete walls are proposed under MCER-level.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4247951
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV