dc.description.abstractA single table permits the designer of architectural glazing systems to select glazing constructions that will meet specified design wind loads. This simplification of the glazing construction selection process employs, as working elements, the minimum load resistance of commonly used glass thicknesses and opening areas. The process is based on two principal observations: (1) heat-treated lites (heat strengthened and fully tempered) with relatively large areas of approximately 4.6–6.5 m2 (5–7 ft2) can carry relatively large design pressures in excess of 4.8 kPa (1 psf) acting alone, thus eliminating the need for load-sharing analysis in most common sizes of insulating glass units; and (2) the load resistances of commonly used monolithic and polyvinylbutyral-laminated lites with identical dimensions and designated thickness are close enough to be considered equal, within 14 Pa (3 psf).
dc.publisherAmerican Society of Civil Engineers
dc.titleSelection of Architectural Glazing Constructions without Calculations
dc.typeJournal Paper
dc.journal.volume24
dc.journal.issue1
dc.journal.titleJournal of Architectural Engineering
dc.identifier.doi10.1061/(ASCE)AE.1943-5568.0000292
dc.page4017036
dc.treeJournal of Architectural Engineering:;2018:;Volume ( 024 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record