Show simple item record

dc.contributor.authorFarzad Nikfar
dc.contributor.authorDimitrios Konstantinidis
dc.date.accessioned2017-12-30T13:05:45Z
dc.date.available2017-12-30T13:05:45Z
dc.date.issued2017
dc.identifier.other%28ASCE%29CP.1943-5487.0000615.pdf
dc.identifier.urihttp://138.201.223.254:8080/yetl1/handle/yetl/4245527
dc.description.abstractDuring an earthquake, freestanding equipment and contents in a building may experience large complex 3D motion. Depending on the geometry, mass distribution, and support mechanism (e.g., wheels, casters, legs) of the object, this motion may include rolling, sliding, twisting, and rocking—potentially resulting in overturning or impact with building occupants, neighboring walls or other objects. Measuring this complex motion by traditional, contact-type displacement sensors is challenging. Owing to recent advances in video capture sensors and image processing techniques, vision-based motion tracking and measurement have been introduced as a practical, economical, and fairly accurate measuring method. This paper presents a procedure utilized to evaluate the accuracy of a consumer-grade camera for the purpose of measuring the motion of a piece of medical equipment during shake-table testing. The fixed-focal length camera considered in this study can capture video recordings with different resolution and frame rates. During experimental testing, the camera is positioned at a distance from the target (as it would be in a real application) to track the motion of four LED lights attached to the shake table. The capabilities of the camera are evaluated using as input a signal with varying frequency and amplitude. A wavelet approach is proposed and utilized in order to synchronize the vision-based displacement measurement with the output of the displacement transducer installed on the shake table, to be later used in accuracy assessments. Absolute and relative error curves are presented to evaluate the errors in the frequency range of interest for the actual experiments. Finally, contour plots are proposed that specify the displacement, velocity, and acceleration accuracy of vision-based measurements, which can be used in future applications.
dc.publisherAmerican Society of Civil Engineers
dc.titleEvaluation of Vision-Based Measurements for Shake-Table Testing of Nonstructural Components
dc.typeJournal Paper
dc.journal.volume31
dc.journal.issue2
dc.journal.titleJournal of Computing in Civil Engineering
dc.identifier.doi10.1061/(ASCE)CP.1943-5487.0000615
dc.page04016050
dc.treeJournal of Computing in Civil Engineering:;2017:;Volume ( 031 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record