• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Shaking Table Performance of a New Bridge System with Pretensioned Rocking Columns

    Thumbnail
    View/Open
    %28ASCE%29BE.1943-5592.0000867.pdf (2.756Mb)
    Date
    2016
    Author
    Travis Thonstad
    Islam M. Mantawy
    John F. Stanton
    Marc O. Eberhard
    David H. Sanders
    Metadata
    Show full item record
    Abstract
    A new bridge bent system has been developed to reduce on-site construction time, minimize residual displacements even after a large earthquake, and reduce seismic damage in comparison with conventional cast-in-place construction. Accelerated construction is achieved through the use of precast columns and cap beams that can be assembled quickly. Postearthquake residual displacements are reduced by pretensioning the columns with partially unbonded tendons. Damage in the columns is nearly eliminated by concentrating flexural deformations to specially detailed regions at the top and bottom of the columns. In this study, the seismic performance of the new system was evaluated with a multi-shaking table test of a quarter scale, two-span bridge at the Network for Earthquake Engineering Simulation (NEES) Earthquake Engineering Laboratory at the University of Nevada, Reno. The maximum displacements of the bents were similar to those expected for a conventional bridge through the 100% design-level event [peak ground acceleration (PGA) = 0.75 g]. Residual drift ratios never exceeded 0.2% up to the 221% design-level motion (PGA = 1.66 g). Damage to the column concrete was negligible; the columns would not need any repair after being subjected to the 100% design-level motion. The only structural damage to the bridge was the eventual fracture of the column’s longitudinal reinforcement and bulging of the column’s confining tube, both of which occurred at drift ratios of approximately 6%. These damage states could be delayed by increasing the debonded length of the deformed bar reinforcement at the ends of the columns and by using a thicker steel tube for the confining detail.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4245174
    Collections
    • Journal of Bridge Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV