    Robustness of Load and Resistance Design Factors for RC Columns with Wind-Dominated Combination Considering Random Eccentricity

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0001720.pdf (1.286Mb)
    Date
    2017
    Author
    Youbao Jiang
    Hao Zhou
    Michael Beer
    Lei Wang
    Jianren Zhang
    Linjie Zhao
    Metadata
    Show full item record
    Abstract
    Based on the capacity models in the 2008 edition of the American Concrete Institute (ACI) Standard Building Code Requirements for Structural Concrete, a more realistic limit state function is built for reinforced concrete columns with random eccentricity. Then, we discuss the applicability of the load and resistance factors in the code, which is mainly based on reliability calibrations with a fixed eccentricity criterion. Taking the wind-dominated combination as an example, representative cases are established by selecting typical values of four related design parameters. Using the load and resistance models in previous reliability calibration of the code, the probabilistic distribution of eccentricity and the statistics of column resistance are analyzed for each case. The analysis indicates that the possible eccentricity shows a scatter over a large range, and the probabilistic model of column resistance varies from case to case, which is largely different from the constant resistance model assumed in previous reliability calibration. With Monte Carlo simulation (MCS), the column reliability is calculated and obtained for different cases. The results show that the fixed eccentricity criterion underestimates the reliability differences among cases and overestimates the column reliability in some tension failure cases. To attain a robust design, an improved measure is recommended by selecting optimum wind load factors varying with cases. The new calibration results prove that the recommended measures can achieve the goal better.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4244570
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV