Show simple item record

dc.contributor.authorYu-Li Dong
dc.contributor.authorXing-Qian Peng
dc.contributor.authorYuan-Yuan Fang
dc.contributor.authorDa-Shan Zhang
dc.date.accessioned2017-12-30T13:00:18Z
dc.date.available2017-12-30T13:00:18Z
dc.date.issued2016
dc.identifier.other%28ASCE%29ST.1943-541X.0001369.pdf
dc.identifier.urihttp://138.201.223.254:8080/yetl1/handle/yetl/4244407
dc.description.abstractThe experimental results of three full-scale two-story, two-bay, composite steel frames under furnace loading are described briefly. During tests, the composite beams and steel columns were exposed to fire, and only the beam-to-column connections of the tested frames were protected. The furnace temperature, composite steel beam temperature, steel column temperature, horizontal displacements of the columns, and vertical deflections of the composite beams as well as the complete deformation process of the test frames observed during the heating phase and the cooling phase are given. By introducing the slope-deflection equations and joint equilibrium conditions at each joint, the critical temperatures of the buckling of two-story, two-bay, composite steel frames are determined for different furnace scenarios; therefore, this method can consider the effect of the axial force at different levels. The calculated critical temperatures agree well with the experimental results.
dc.publisherAmerican Society of Civil Engineers
dc.titleBehavior of Sway Two-Bay, Two-Story Composite Steel Frames in Fire
dc.typeJournal Paper
dc.journal.volume142
dc.journal.issue2
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0001369
dc.page04015119
dc.treeJournal of Structural Engineering:;2016:;Volume ( 142 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record