Show simple item record

dc.contributor.authorCarlos Molina Hutt
dc.contributor.authorIbrahim Almufti
dc.contributor.authorMichael Willford
dc.contributor.authorGregory Deierlein
dc.date.accessioned2017-12-30T13:00:02Z
dc.date.available2017-12-30T13:00:02Z
dc.date.issued2016
dc.identifier.other%28ASCE%29ST.1943-541X.0001314.pdf
dc.identifier.urihttp://138.201.223.254:8080/yetl1/handle/yetl/4244361
dc.description.abstractIn areas of high seismicity in the United States, the design of many existing tall buildings followed guidelines that do not provide an explicit understanding of performance during major earthquakes. This paper presents an assessment of the seismic performance of existing tall buildings and strategies for increased resilience for a case study city, San Francisco, where an archetype tall building is designed based on an inventory of the existing tall building stock. A 40-story moment-resisting frame system is selected as a representative tall building. The archetype building is rectangular in plan and represents the state of design and construction practice from the mid-1970s to the mid-1980s. Nonlinear response history analysis (NLRHA) are conducted with ground motions representative of the design earthquake hazard level defined in current building codes, with explicit consideration of near-fault directivity effects. Mean transient interstory drifts and story accelerations under the 10% in 50-year ground motion hazard range from 0.19 to 1.14% and 0.15 to 0.81 g, respectively. In order to influence decision making, performance is reported as the expected consequences in terms of direct economic losses and downtime. Furthermore, to achieve increased levels of resilience, a number of strategies are proposed including seismic improvements to structural and nonstructural systems as well as mitigation measures to minimize impeding factors. Expected direct economic losses for the archetype building are in the order of 34% of building cost and downtime estimates for functional recovery are 87 weeks. The strategies presented in this paper enable up to a 92% reduction in losses and minimize downtime for functional recovery to 1 day or less.
dc.publisherAmerican Society of Civil Engineers
dc.titleSeismic Loss and Downtime Assessment of Existing Tall Steel-Framed Buildings and Strategies for Increased Resilience
dc.typeJournal Paper
dc.journal.volume142
dc.journal.issue8
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0001314
dc.pageC4015005
dc.treeJournal of Structural Engineering:;2016:;Volume ( 142 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record