    The Effects of Prosthesis Inertial Parameters on Inverse Dynamics: A Probabilistic Analysis

    Thumbnail
    View/Open
    vvuq_002_03_031003.pdf (1.167Mb)
    Date
    2017
    Author
    Gaffney
    Brecca M. M.;Christiansen
    Cory L.;Murray
    Amanda M.;Myers
    Casey A.;Laz
    Peter J.;Davidson
    Bradley S.
    Metadata
    Show full item record
    Abstract
    Joint kinetic measurement is a fundamental tool used to quantify compensatory movement patterns in participants with transtibial amputation (TTA). Joint kinetics are calculated through inverse dynamics (ID) and depend on segment kinematics, external forces, and both segment and prosthetic inertial parameters (PIPS); yet the individual influence of PIPs on ID is unknown. The objective of this investigation was to assess the importance of parameterizing PIPs when calculating ID using a probabilistic analysis. A series of Monte Carlo simulations were performed to assess the influence of uncertainty in PIPs on ID. Multivariate input distributions were generated from experimentally measured PIPs (foot/shank: mass, center of mass (COM), moment of inertia) of ten prostheses and output distributions were hip and knee joint kinetics. Confidence bounds (2.5–97.5%) and sensitivity of outputs to model input parameters were calculated throughout one gait cycle. Results demonstrated that PIPs had a larger influence on joint kinetics during the swing period than the stance period (e.g., maximum hip flexion/extension moment confidence bound size: stance = 5.6 N·m, swing: 11.4 N·m). Joint kinetics were most sensitive to shank mass during both the stance and swing periods. Accurate measurement of prosthesis shank mass is necessary to calculate joint kinetics with ID in participants with TTA with passive prostheses consisting of total contact carbon fiber sockets and dynamic elastic response feet during walking.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4242921
    Collections
    • Journal of Verification, Validation and Uncertainty Quantification

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV