• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Empirical Approach to Evaluating the Tornado Fragility of Residential Structures

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0001854.pdf (937.1Kb)
    Date
    2017
    Author
    David B. Roueche
    Franklin T. Lombardo
    David O. Prevatt
    Metadata
    Show full item record
    Abstract
    Tornado-induced wind load modeling has advanced significantly in recent years, but comparison of the experimental or numerical models to observed tornado damage is limited. This paper describes the development of empirically derived tornado fragility functions for residential structures following the 22 May 2011 Joplin, Missouri tornado. The fragility functions were created by combining a residential structure damage assessment of the Joplin tornado using the enhanced Fujita (EF) scale and a tornado wind field model conditioned to tree-fall patterns. The damage states for the fragility functions used the degrees of damage (DOD) for one- and two-story residential structures from the EF scale. The empirical tornado fragility functions were compared to analytically derived fragility functions for straightline winds from the FEMA Hazus hurricane model to provide a first attempt at ascertaining how different or similar failure wind speeds are for residential structures under tornado-induced and straightline wind loads. Median failure wind speeds from the empirical tornado fragility functions increased monotonically with DOD, from 33.4  m/s for DOD1 to 85.6  m/s for DOD9. Median failure wind speeds of the empirical tornado fragility functions and Hazus hurricane straightline wind fragility functions differed by 5% or less when suburban terrain was assumed throughout the damage path, and 25% or less when open terrain was assumed. The results suggest that tornado load amplification factors are at worst no more than 55% for residential structures, and may be lower than 10%.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4242560
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV