• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Water Resources Planning and Management
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Water Resources Planning and Management
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Model-Based Event Detection for Contaminant Warning Systems

    Thumbnail
    View/Open
    %28ASCE%29WR.1943-5452.0000689.pdf (1.182Mb)
    Date
    2016
    Author
    Xueyao Yang
    Dominic L. Boccelli
    Metadata
    Show full item record
    Abstract
    Security issues have become increasingly important within distribution systems, which have led to the development of event detection algorithms (EDAs) to provide timely detection of intrusion events. The current study develops a localized model-based event detection algorithm that utilizes nonspecific water quality sensors to identify water quality anomalies. The proposed EDA focuses on evaluating a series of multivariate error signals between the observed signals and the model estimated signals based on a moving time-window of error statistics. The likelihood of the multivariate error signals is estimated using the product of univariate kernel density estimation (KDE), which is a type of nonparametric representation of the error distribution. A comprehensive analysis was performed using synthetic events to explore the combination of the moving window-pairs and bandwidth with respect to three injection strengths and two injection durations. In addition to the synthetic events, the EDA was also evaluated using a more realistic approach that simulates the water quality parameters in response to two real contaminants (KCN and nicotine) based on previously developed water quality dynamic models. Overall, the model-based EDA was capable of detecting anomalous water quality events through the statistical evaluation of multivariate error signals with performance related to the magnitude of the event. The results indicate that smaller events resulting from hydraulic/transport dynamics can have a significant impact on the EDA performance, which are not typically considered in most EDA evaluations. The results of the proposed EDA also illustrate that sensor performance should be considered within other water security activities such as the optimal design of sensor-based contaminant warning systems.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4242228
    Collections
    • Journal of Water Resources Planning and Management

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 