    Rational Approach for Evaluating Fire Resistance of FRP-Strengthened Concrete Beams

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0000697.pdf (496.4Kb)
    Date
    2016
    Author
    V. K. R. Kodur
    B. Yu
    Metadata
    Show full item record
    Abstract
    This paper presents a rational approach for evaluating the fire resistance of reinforced concrete (RC) beams strengthened with different types of fiber-reinforced polymers (FRP). This approach is based on conventional fire design principles for RC beams, but incorporates the contribution of FRP and fire insulation in fire resistance calculations. Simplified equations are proposed for evaluating cross-sectional temperatures in fire-exposed FRP-strengthened RC beams with and without fire insulation. These temperatures are used to determine the loss of strength in steel, FRP, and concrete using temperature-dependent strength properties. Employing the strength in different materials, the moment capacity of FRP-strengthened beams is calculated, at any given fire exposure time, by applying force equilibrium and strain compatibility principles. At each time step, the limit state is applied to define the failure of an FRP-strengthened RC beam, and the time to failure is taken as the fire resistance of the beam. The validity of the proposed approach is established by comparing predicted fire response parameters with those obtained from fire resistance tests and detailed finite-element analyses. Further, the applicability of the proposed approach in practical situations is illustrated through a design example. Results from the proposed approach clearly indicate that a typical FRP-strengthened beam without supplemental fire insulation experiences a significant loss of moment capacity after approximately 20 min into fire exposure. However, a similar FRP-strengthened beam with supplemental fire insulation retains much of its moment capacity until 2 h into fire exposure.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4241673
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV