    Strengthening by Stiffening: Fiber-Reinforced Plastic Configuration Effects on Behavior of Shear-Deficient Steel Beams

    Thumbnail
    View/Open
    %28ASCE%29CC.1943-5614.0000788.pdf (4.665Mb)
    Date
    2017
    Author
    Tuna Ulger
    Ayman M. Okeil
    Metadata
    Show full item record
    Abstract
    Restoring the capacity of deficient structural members to meet original design requirements or new higher demands is common. For that purpose, research efforts to use composite materials in retrofitting steel structures have been gradually gaining ground in recent years, with more focus on inhibiting buckling modes by increasing local and/or global member stiffness. In this paper, the authors experimentally investigate retrofitting alternatives for shear-deficient steel structures. The proposed alternatives fall on what is referred to as strengthening by stiffening (SBS), in which thin-walled steel beams are retrofitted by bonding pultruded glass fiber reinforced polymer (GFRP) sections to the buckling-prone web panels. Different GFRP stiffener orientations, types, and adhesives were investigated in addition to conventional welded steel stiffeners, and bonded biaxial carbon fiber reinforced polymer (CFRP) sheets were tested in this study. The experimental results showed that gains in shear strength of up to 81% compared to non-retrofitted beams were achieved with bonded CFRP sheets, whereas an increase of about 50% in load capacity was achieved for bonded GFRP and welded steel stiffeners. The energy ductility of the retrofitted beams was found to be higher when a ductile epoxy type was used. Recommendations regarding the number of GFRP stiffeners, their orientation, type, and adhesive properties were drawn based on the findings from this paper. The results also showed that it may be possible to use SBS in new construction to eliminate conventionally welded steel stiffeners, which is known to introduce stress concentrations and their associated fatigue problems.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4241618
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV