    Influence of Supply-Channel Velocity on Farm Delivery Meter Gate Flow Measurement

    Thumbnail
    View/Open
    %28ASCE%29IR.1943-4774.0001180.pdf (231.0Kb)
    Date
    2017
    Author
    Daniel J. Howes
    Charles M. Burt
    John M. Thorburn
    Metadata
    Show full item record
    Abstract
    The work presented here is an extension of previous papers that updated the calibration of round (Armco-type) meter gates (three sizes: 0.30, 0.46, and 0.61 m), developed ratings for rectangular gates (two sizes: 0.46 and 0.61 m) on round pipes, and examined errors and uncertainty related to using these devices for water discharge measurement. Previous works examined gate discharge ratings under low supply-channel flow velocity perpendicular to the gate discharge pipeline. Here, additional testing was conducted to test the hypothesis that higher velocities in the supply channel would show decreased meter gate flow compared to the low-velocity ratings, but that the published gate calibration method would still yield accurate flow-rate calculations. All testing was conducted in a test facility with the gate discharge pipe set perpendicular to the supply channel, as is common in field installations. Velocities up to 0.94  m/s (3.1  ft/s) were tested with the smaller gate and 0.66  m/s (2.2  ft/s) for all other gates. These velocities are on the upper end of velocities found in common earthen irrigation canals (and in many lined channels at the farm delivery level) in California. Interestingly, results indicate that the Froude number of the supply-channel flow did not have a statistically significant (at an α-level of 0.01) influence on gate discharge coefficients. Discharge percent error and uncertainty were examined to compare the discharge coefficients presented in the literature to the discharge measured during the testing at different supply-channel velocities. Under recommended operating conditions, the uncertainty was within ±5% without adjustments for supply-channel velocity. This extended work supports earlier recommendations that meter gates can be an accurate flow measurement device for farm water delivery flow measurement if installed and operated correctly.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4238614
    Collections
    • Journal of Irrigation and Drainage Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV