Improvements in Standardized Testing for Evaluating Sediment Barrier Performance: Design of a Full-Scale Testing Apparatus
Abstract
Perimeter controls [i.e., sediment barriers (SBs) or sediment retention devices] are typically used on construction sites to retain sediment and prevent polluted stormwater runoff from adversely affecting aquatic habitats and clogging storm sewers. Often, parameters based on rule-of-thumb are applied to the design of SBs without knowing their expected performance capabilities. This issue is further complicated by the difficulty in devising a scientifically sound, repeatable testing methodology, replicating field conditions to assess performance. To resolve this issue, a test apparatus was designed and constructed at the Auburn University—Erosion and Sediment Control Test Facility to replicate in-field rainfall runoff rates for purposes of conducting full-scale experiments on various SBs. This apparatus allows for performance testing and direct comparisons between various SB products, practices, and installations. The overall intent of conducting full-scale testing is to improve design criteria and enhance the in-field performance of SB practices. Initial test results for a woven polypropylene silt fence reinforced with a polypropylene grid and supported by wooden posts performed well structurally with an average sediment retention rate of 90.5% by volume.