Show simple item record

dc.contributor.authorSai Ganesh S. Pai
dc.contributor.authorFrank Lam
dc.contributor.authorTerje Haukaas
dc.date.accessioned2017-12-16T08:59:01Z
dc.date.available2017-12-16T08:59:01Z
dc.date.issued2017
dc.identifier.other%28ASCE%29ST.1943-541X.0001674.pdf
dc.identifier.urihttp://138.201.223.254:8080/yetl1/handle/yetl/4237087
dc.description.abstractThis paper presents a study on force transfer around openings (FTAO) in cross-laminated timber (CLT) shear walls. To elucidate the load transfer mechanism in CLT walls, this study used finite-element models to study five different CLT shear wall configurations. The effect of uncertainty in the behavior of connectors in the wall over its force-deformation behavior and design transfer force was also studied. In a coupled-panel wall, the presence of an opening decreased the strength and stiffness of the wall and tie-rods were provided as reinforcement to limit the deformation between the panels in the wall and to improve its strength and stiffness. The models presented here provide a tool to determine the transfer force in a CLT shear wall for design of tie-rods and develop a better understanding of load distribution within the wall.
dc.publisherAmerican Society of Civil Engineers
dc.titleForce Transfer around Openings in Cross-Laminated Timber Shear Walls
dc.typeJournal Paper
dc.journal.volume143
dc.journal.issue4
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0001674
dc.treeJournal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 004
dc.contenttypeFulltext