| dc.contributor.author | Michael G. Gray | |
| dc.contributor.author | Constantin Christopoulos | |
| dc.contributor.author | Jeffrey A. Packer | |
| dc.date.accessioned | 2017-12-16T08:58:56Z | |
| dc.date.available | 2017-12-16T08:58:56Z | |
| dc.date.issued | 2017 | |
| dc.identifier.other | %28ASCE%29ST.1943-541X.0001692.pdf | |
| dc.identifier.uri | http://138.201.223.254:8080/yetl1/handle/yetl/4237071 | |
| dc.description.abstract | The yielding brace system (YBS) is a seismic-resistant concentrically braced frame system that provides a fully symmetric hysteretic response via flexural yielding of cast steel triangular yielding fingers of a specially designed yielding connector. The behavior of the system is first reviewed, and a detailed discussion of the limit states design of a YBS braced frame is presented. Results of two full-scale yielding connector prototype tests, conducted in a braced frame configuration, are then presented. The test specimens were subjected to several quasi-static and dynamic load cycles, up to axial brace deformations of 120 mm (3.8% interstory drift). The proposed design limit states were validated through full-scale testing and the performance of a YBS yielding connector brace assembly in a typical braced frame with a bolted brace-to-gusset connection was demonstrated to be very similar to the performance of YBS yielding connectors tested in a purely axial configuration. | |
| dc.publisher | American Society of Civil Engineers | |
| dc.title | Design and Full-Scale Testing of a Cast Steel Yielding Brace System in a Braced Frame | |
| dc.type | Journal Paper | |
| dc.journal.volume | 143 | |
| dc.journal.issue | 4 | |
| dc.journal.title | Journal of Structural Engineering | |
| dc.identifier.doi | 10.1061/(ASCE)ST.1943-541X.0001692 | |
| dc.tree | Journal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 004 | |
| dc.contenttype | Fulltext | |