• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Experimental Performance Assessment of Nearly Full-Scale Reinforced Concrete Columns with Partially Debonded Longitudinal Reinforcement

    Thumbnail
    View/Open
    %28ASCE%29ST.1943-541X.0001708.pdf (3.383Mb)
    Date
    2017
    Author
    M. T. Nikoukalam
    P. Sideris
    Metadata
    Show full item record
    Abstract
    This paper presents an experimental study investigating the effect of partial debonding of longitudinal reinforcement at the location of the plastic hinge on the performance of reinforced concrete columns in special moment-resisting frames designed for seismic regions as per standard guidelines. Partial debonding is investigated as a means of spreading locally induced deformations over larger rebar lengths, thereby preventing early rebar yielding and fracture and improving the seismic performance of the columns. The experimental program, which was conducted at the University of Colorado Boulder, included quasi-static cyclic testing of three nearly full-scale (∼1∶1.14 or ∼88%) cantilever columns with various debonded reinforcement lengths. The experimental findings showed that reinforcement debonding resulted in early onset of concrete cracking and delayed reinforcement yielding. Spreading of concrete damage decreased with the debonded length, not exceeding half of the plastic hinge length (as opposed to the full plastic hinge length for bonded reinforcement). Debonding alleviated strain localizations in the steel reinforcement, at least, for drift ratios below 2%. The peak strength and initial elastic stiffness decreased with the debonded length. Energy dissipation and equivalent viscous damping ratio increased with the debonded length for drift ratios below 2%, and decreased with the debonded length for drift ratios exceeding 3%. Self-centering improved with the debonded length.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4237058
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV