• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Electronic Packaging
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Electronic Packaging
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Transient Data Processing of Flow Boiling Local Heat Transfer in a Multi-Microchannel Evaporator Under a Heat Flux Disturbance

    Thumbnail
    View/Open
    ep_139_01_011005.pdf (4.177Mb)
    Date
    2017
    Author
    Huang, Houxue
    Lamaison, Nicolas
    Thome, John R.
    Metadata
    Show full item record
    Abstract
    Multi-microchannel evaporators are often used to cool down electronic devices subjected to continuous heat load variations. However, so far, rare studies have addressed the transient flow boiling local heat transfer data occurring in such applications. The present paper introduces and compares two different data reduction methods for transient flow boiling data in a multi-microchannel evaporator. A transient test of heat disturbance from 20 to 30 W cm−2 was conducted in a multi-microchannel evaporator using R236fa as the test fluid. The test section was 1 × 1 cm2 in size and had 67 channels, each having a cross-sectional area of 100 × 100 μm2. The micro-evaporator backside temperature was obtained with a fine-resolution infrared (IR) camera. The first data reduction method (referred to three-dimensional (3D)-TDMA) consists in solving a transient 3D inverse heat conduction problem by using a tridiagonal matrix algorithm (TDMA), a Newton–Raphson iteration, and a local energy balance method. The second method (referred to two-dimensional (2D)-controlled) considers only 2D conduction in the substrate of the micro-evaporator and solves at each time step the well-posed 2D conduction problem using a semi-implicit solver. It is shown that the first method is more accurate, while the second one reduces significantly the computational time but led to an approximated solution. This is mainly due to the 2D assumption used in the second method without considering heat conduction in the widthwise direction of the micro-evaporator.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4236837
    Collections
    • Journal of Electronic Packaging

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV