dc.description.abstractSuper-twisting algorithm, a second-order sliding mode control method, is studied for hydropower plant frequency control. Two versions of this algorithm are introduced in this paper. Simulation results from both of these second-order methods and regular sliding mode control are compared on the basis of system responses and control efforts. It is shown that the second-order sliding mode controller is able to reduce chattering effects associated with the regular sliding mode control and preserve the robustness of the regular sliding mode control as well.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleHydropower Plant Load Frequency Control Via Second-Order Sliding Mode
dc.typeJournal Paper
dc.journal.volume139
dc.journal.issue7
dc.journal.titleJournal of Dynamic Systems, Measurement, and Control
dc.identifier.doi10.1115/1.4035744
dc.journal.fristpage74503
dc.journal.lastpage074503-5