• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Quasi Two-Dimensional Flow-Adaptive Algorithm for Pneumatic Probe Measurements

    Thumbnail
    View/Open
    ds_139_07_071011.pdf (1.940Mb)
    Date
    2017
    Author
    Bartsch, Christian
    Hölle, Magnus
    Jeschke, Peter
    Metzler, Timo
    Metadata
    Show full item record
    Abstract
    The subject of this paper is a flow-adaptive measurement grid algorithm developed for one-dimensional (1D) and two-dimensional (2D) flow field surveys with pneumatic probes in turbomachinery flows. The algorithm automatically determines the distribution and the amount of measurement points needed for an approximation of the pressure distribution within a predefined accuracy. The algorithm is based on transient traverses, conducted back and forth in the circumferential direction. A correction of the dynamic response is applied by deconvolving the transient measurement data using the information embedded in both transient measurements. In consequence, the performance of the algorithm is largely independent of the transient traversing speed and the geometry of the pressure measuring system. Insertion and removal strategies are incorporated in order to reduce measurement points and increase robustness toward differing flow field conditions. The performance of the algorithm is demonstrated for 2D flow field surveys with a pneumatic five-hole probe in an annular cascade wind tunnel. The measurement grid points are automatically adjusted so that a consistent resolution of the flow features is achieved within the measurement domain. Furthermore, the application of the algorithm shows a significant reduction in the number of measurement points. Compared to the measurement duration based on uniform grids, the duration is reduced by at least 7%, while maintaining a high accuracy of the measurement. The purpose of this paper is to demonstrate the performance of measurement grids adapted to local flow field conditions. Consequently, valuable measurement time can be saved without a loss in quality of the data obtained.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4236668
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV