    Abstract
    Electrohydrostatic actuators (EHAs), as a class of pump-controlled hydraulic actuators, are known for energy efficiency and easy maintainability. Thus, they can be widely used in the situations where actuating pressure/force control of hydraulic actuators is essential. Examples are automotive active suspension, deep-drawing press, molding machine, and vibration isolation. However, a leaky piston seal in an EHA system can be especially problematic as it is not visually detectable, but causes internal leakage flowing across actuator chambers impairing the performance. This paper employs quantitative feedback theory (QFT) to design a robust fixed-gain linear actuating pressure controller that is tolerant to actuator internal leakage. Since QFT captures uncertainties by templates, representing frequency responses of the plant on Nichols chart, the first step, to design a QFT controller, is to establish plant templates. In doing so, a set of offline parametric system identifications are implemented, and the family of identified models, providing frequency responses, are used to design the QFT fault-tolerant controller. The controller also satisfies the prescribed design tolerances on tracking, stability and sensitivity (disturbance rejection at plant output) under different conditions, including various levels of actuator internal leakage, environmental stiffnesses, and load masses. The ability of the controller to maintain actuating pressure within the acceptable response envelope is demonstrated in experiments. The experimental results show that the system specifications are satisfied despite internal leakage up to 12 L/min.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4236643
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV