dc.description.abstractAxial pipeline defects are detectable from torsional guided wave reflections through 90 deg elbows. This paper demonstrates that detection of localized damage in carbon steel pipes with a so-called standard long and very long radius elbow is possible using a single permanently installed source–receiver pair. We use dispersion imaging to determine why this is not possible in a short radius elbow pipe. Although the remote damage is detected in a standard short radius bend pipe, there is not enough signal to detect localized damage. Since pipeline bends are normally of at least standard long radius, the acoustical behavior is similar to that previously determined in straight pipes. The reflective method can thus be applied fruitfully to monitor structural health beyond industrial pipeline bends.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleDamage Detection Through Pipe Bends
dc.typeJournal Paper
dc.journal.volume139
dc.journal.issue5
dc.journal.titleJournal of Pressure Vessel Technology
dc.identifier.doi10.1115/1.4037120
dc.journal.fristpage51701
dc.journal.lastpage051701-7