• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Assessing the Importance of Surgeon Hand Anthropometry on the Design of Medical Devices

    Thumbnail
    View/Open
    med_011_04_041004.pdf (446.4Kb)
    Date
    2017
    Author
    Stellon, Michael
    Seils, Drew
    Mauro, Christine
    Metadata
    Show full item record
    Abstract
    Improperly designed medical devices can induce unwanted biomechanical stressors on their users, impacting health and career longevity. Despite this, manufacturers struggle to balance device design with the growing female surgeon population. We have applied anthropometry to a population of surgeon hands as an alternative to preferred glove size. Correlations to physical dimensions of two laparoscopic staplers were assessed. Five anthropometric measurements were taken from dominant hands of surgeons. These measurements were selected with the goal of comparing resulting data to published anthropometry studies and assessing correlation to preferred glove size and instrument design. The trigger reach of the two laparoscopic staplers were measured to assess suitability among the surgeon population surveyed. Fifty eight surgeons (50 male, 8 female), average glove size 7.5 and 6.0, were measured. Data indicate that male surgeons had significantly larger hands than female. Hand circumference displayed a relatively strong positive correlation with preferred glove size (0.799, R2 = 63.9%); other measurements did not. The trigger span of one stapler was found suitable for only 78.2% of male and 30.9% of female surgeons, based on comparisons with anthropometry of the surveyed population. Anthropometry should be used to characterize surgeon hands instead of preferred glove size. Also, from the limited scope of this research, discrepancies exist between the size of the surgeon hand and the devices designed for their use. The use of inappropriately designed instrumentation can cause musculoskeletal injury, decreased productivity, and shortened careers. Manufacturers would benefit by consulting anthropometry databases to develop products.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4235251
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV