    Feasibility Assessment of Microwave Ablation for Treating Esophageal Varices

    Thumbnail
    View/Open
    med_011_03_031013.pdf (2.037Mb)
    Date
    2017
    Author
    Sebek, Jan
    Curto, Sergio
    Eaton-Evans, Jimmy
    Bouchier-Hayes, Jonathan
    Ruvio, Giuseppe
    Ganta, Chanran
    Beard, Warren
    Buttar, Navtej
    Song, Louis Wong Kee
    Prakash, Punit
    Metadata
    Show full item record
    Abstract
    Esophageal varices are a significant complication of portal hypertension. Endoscopic variceal ligation (EVL) is one of the clinical standards for treating these varices and preventing their hemorrhage. Limitations of EVL include the risk of stricture formation and postband ulcer bleeding due to the damage caused to the esophageal mucosa, as well as the need for multiple endoscopic treatment sessions to eradicate the varices. The goal of this study is to develop a device and evaluate the technical feasibility of microwave ablation to seal esophageal varices, while preventing thermal damage to the surface mucosal tissue. A microwave applicator with a directional radiation pattern was developed for endoscopic ablation of esophageal varices. Electromagnetic and bioheat transfer computational models were employed to optimize the design of the microwave applicator and evaluate energy delivery strategies for this application. Experiments in ex vivo and in vivo tissue were employed to verify simulation results. Simulations predicted enhanced heating performance of the antenna using an angled monopole radiating element. Further, simulations indicate that while the endoscopic cap attenuated electric fields in tissue, it also enhanced surface cooling of tissue, increasing the likelihood of preserving mucosal tissue. Experiments in ex vivo tissue indicated the feasibility of sealing veins with 77 W microwave power delivered for 30 s. In vivo experiments demonstrated the ability to seal veins, while preserving surface tissue. This study demonstrated the technical feasibility of microwave thermal ablation for treating esophageal varices using a 2.45 GHz water-cooled directional microwave applicator.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4235238
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV