Show simple item record

dc.contributor.authorOguz, Gokce Nur
dc.contributor.authorPiskin, Senol
dc.contributor.authorErmek, Erhan
dc.contributor.authorDonmazov, Samir
dc.contributor.authorAltekin, Naz
dc.contributor.authorArnaz, Ahmet
dc.contributor.authorPekkan, Kerem
dc.date.accessioned2017-11-25T07:18:31Z
dc.date.available2017-11-25T07:18:31Z
dc.date.copyright2017/3/5
dc.date.issued2017
dc.identifier.issn1932-6181
dc.identifier.othermed_011_02_021012.pdf
dc.identifier.urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235220
dc.description.abstractThe hemodynamic energy loss through the surgically implanted conduits determines the postoperative cardiac output and exercise capacity following the palliative repair of single-ventricle congenital heart defects. In this study, the hemodynamics of severely deformed surgical pathways due to torsional deformation and anastomosis offset are investigated. We designed a mock-up total cavopulmonary connection (TCPC) circuit to replicate the mechanically failed inferior vena cava (IVC) anastomosis morphologies under physiological venous pressure (9, 12, 15 mmHg), in vitro, employing the commonly used conduit materials: Polytetrafluoroethylene (PTFE), Dacron, and porcine pericardium. The sensitivity of hemodynamic performance to torsional deformation for three different twist angles (0 deg, 30 deg, and 60 deg) and three different caval offsets (0 diameter (D), 0.5D, and 1D) are digitized in three dimensions and employed in computational fluid dynamic (CFD) simulations to determine the corresponding hydrodynamic efficiency levels. A total of 81 deformed conduit configurations are analyzed; the pressure drop values increased from 80 to 1070% with respect to the ideal uniform diameter IVC conduit flow. The investigated surgical materials resulted in significant variations in terms of flow separation and energy loss. For example, the porcine pericardium resulted in a pressure drop that was eight times greater than the Dacron conduit. Likewise, PTFE conduit resulted in a pressure drop that was three times greater than the Dacron conduit under the same venous pressure loading. If anastomosis twist and/or caval offset cannot be avoided intraoperatively due to the anatomy of the patient, alternative conduit materials with high structural stiffness and less influence on hemodynamics can be considered.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleIncreased Energy Loss Due to Twist and Offset Buckling of the Total Cavopulmonary Connection
dc.typeJournal Paper
dc.journal.volume11
dc.journal.issue2
dc.journal.titleJournal of Medical Devices
dc.identifier.doi10.1115/1.4035981
dc.journal.fristpage21012
dc.journal.lastpage021012-8
dc.treeJournal of Medical Devices:;2017:;volume( 011 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record