• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Medical Devices
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Design, Analysis, and Optimization of an Acute Stroke Gait Rehabilitation Device

    Thumbnail
    View/Open
    med_011_01_014503.pdf (902.9Kb)
    Date
    2017
    Author
    Kora, Kazuto
    Stinear, James
    McDaid, Andrew
    Metadata
    Show full item record
    Abstract
    Stroke is one of the leading causes of adult physical disability, and rehabilitation and hospitalization costs for stroke are among the highest for all injuries. Current rehabilitation techniques are labor intensive and time consuming for therapists and difficult to perform effectively. Research suggests that starting rehabilitation during the acute or subacute stage of recovery results in better outcomes than therapy delivered in the chronic stage. To improve the gait rehabilitation process, robot-assisted gait rehabilitation has gained much interest over the past years. However, many robot-assisted rehabilitation devices have limitations; one of which is being bulky and complex to handle. Large and expensive devices that require special training to operate are less attractive to clinics and therapists, and ultimately less likely to be available to patients especially at the early stage of stroke. To address these limitations, this research proposes a new gait rehabilitation device called the linkage design gait trainer (LGT). The device is based on a walking frame design with a simple four-bar linkage “end-effector” mechanism to generate normal gait trajectories during general walking and exercise. The design of the four-bar linkage mechanism was optimized for a particular gait pattern. A prototype of the device was developed and tested. The kinematics of the device itself and gait kinematics with and without assistance from the device were recorded and analyzed using an optical motion capture system. The results show the linkage mechanism is able to guide the leg of the user during over ground walking. There were some differences in the hip (20.5 deg RMS) and knee (14.8 deg RMS) trajectory between the person walking with and without the device assistance. The study demonstrated the concept and feasibility of this novel gait training device.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4235203
    Collections
    • Journal of Medical Devices

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV