    Comprehensive Experimental and Computational Analysis of a Fully Contained Hybrid Server Cabinet

    Thumbnail
    View/Open
    ht_139_08_082101.pdf (4.435Mb)
    Date
    2017
    Author
    Nemati, Kourosh
    Alissa, Husam A.
    Murray, Bruce T.
    Sammakia, Bahgat G.
    Tipton, Russell
    Seymour, Mark J.
    Metadata
    Show full item record
    Abstract
    The rapid growth in the number of data centers combined with the high-density heat dissipation of computer and telecommunications equipment has made energy efficient thermal management of data centers a key research area. Localized hybrid air–water cooling is one approach to more effectively control the cooling when there is wide variation in the amount of dissipation in neighboring racks while the traditional air cooling approach requires overprovisioning. In a closed, hybrid air–water cooled server cabinet, the generated heat is removed by a self-contained system that does not interact with the room level air cooling system. Here, a hybrid-cooled enclosed cabinet and all its internal components were characterized experimentally in steady-state mode (e.g., experimentally determined heat-exchanger effectiveness and IT characterization). Also, a comprehensive numerical model of the cabinet was developed and validated using the experimental data. The computational model employs full numerical modeling of the cabinet geometry and compact models to represent the servers and the air/water heat exchanger. The compact models were developed based on experimental flow and thermal characterization of the internal components. The cabinet level model has been used to simulate a number of operating scenarios relevant to data center applications such as the effect of air leakage within the cabinet. The effect of the air side and the water side failure of the cooling system on the IT performance were investigated experimentally. A comparison was made of the amount of time required to exceed the operating temperature limit for the two scenarios.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4234299
    Collections
    • Journal of Heat Transfer

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV