    Forming Limit Differences in Hemispherical Dome and Biaxial Test During Equibiaxial Tension on Cruciform

    Thumbnail
    View/Open
    mats_139_04_041011.pdf (3.091Mb)
    Date
    2017
    Author
    Nikhare, Chetan P.
    Vorisek, Emmett
    Nolan, John R.
    Roth, John T.
    Metadata
    Show full item record
    Abstract
    Traditionally, the mechanical properties of materials have been characterized using the uniaxial tension test. This test is considered adequate for simple forming operations where single axis loading is dominant. Previous studies, however, have noted that the data acquired from this type of testing are not enough and additional details in other axes under simultaneous deformation conditions are important. To analyze the biaxial strain, some studies have suggested using the limiting dome height test and bulge test. However, these tests limit the extent of using multi-axial loading and the resulting stress pattern due to contact surfaces. Therefore, researchers devised the biaxial machine which is designed specifically to provide biaxial stress components using multiple and varying loading conditions. The idea of this work is to evaluate the relationship between the dome test data and the biaxial test data. For this comparison, cruciform specimens with a diamond shaped thinner gage in the center were deformed with biaxial stretching on the biaxial testing machine. In addition, the cruciform specimens were biaxially stretched with a hemispherical punch in a conventional die-punch setting. Furthermore, in each case, the process was simulated using a three-dimensional (3D) model generated on abaqus. These models were then compared with the experimental results. The forces on each arm, strain path, forming, and formability were analyzed. The differences between the processes were detailed. It was found that biaxial tests eliminated the pressurization effect which could be found in hemispherical dome tests.
    URI
    http://138.201.223.254:8080/yetl1/handle/yetl/4233924
    Collections
    • Journal of Engineering Materials and Technology

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV