Show simple item record

dc.contributor.authorMunro, D. S.
dc.date.accessioned2017-06-09T17:40:22Z
dc.date.available2017-06-09T17:40:22Z
dc.date.copyright1980/02/01
dc.date.issued1979
dc.identifier.issn0021-8952
dc.identifier.otherams-9858.pdf
dc.identifier.urihttp://onlinelibrary.yabesh.ir/handle/yetl/4233392
dc.description.abstractThe construction and field operation of a portable differential psychrometer system is described. Portability is provided by means of a dc powered ventilation system. Examples of temperature and vapor pressure gradients measured with the apparatus are given. Despite small gradients (?0.01°C m?1; ?1 Pa m?1), Bowen ratios calculated from the data tend to be precise, demonstrating characteristics like those observed elsewhere. It is concluded that the instrumentation expands the scope of differential psychrometry in evaporation studies and other aspects of boundary-layer work.
dc.publisherAmerican Meteorological Society
dc.titleA Portable Differential Psychrometer System
dc.typeJournal Paper
dc.journal.volume19
dc.journal.issue2
dc.journal.titleJournal of Applied Meteorology
dc.identifier.doi10.1175/1520-0450(1980)019<0206:APDPS>2.0.CO;2
dc.journal.fristpage206
dc.journal.lastpage214
dc.treeJournal of Applied Meteorology:;1979:;volume( 019 ):;issue: 002
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record