Show simple item record

dc.contributor.authorFairall, C. W.
dc.contributor.authorDavidson, K. L.
dc.contributor.authorSchacher, G. E.
dc.date.accessioned2017-06-09T17:40:11Z
dc.date.available2017-06-09T17:40:11Z
dc.date.copyright1979/09/01
dc.date.issued1979
dc.identifier.issn0021-8952
dc.identifier.otherams-9775.pdf
dc.identifier.urihttp://onlinelibrary.yabesh.ir/handle/yetl/4233300
dc.description.abstractMicrothermal sensors contaminated by salt aerosol droplets are subject to erroneous temperature fluctuations caused by water vapor exchange in response to fluctuations in humidity. The effect was studied by comparing the values of mean-square temperature fluctuations indicated by contaminated and clean sensors. The effect was negligible for ambient relative humidities above 85%, primarily due to the lack of humidity fluctuations. The errors were significantly diminished by frequent washing of the sensors.
dc.publisherAmerican Meteorological Society
dc.titleHumidity Effects and Sea Salt Contamination of Atmospheric Temperature Sensors
dc.typeJournal Paper
dc.journal.volume18
dc.journal.issue9
dc.journal.titleJournal of Applied Meteorology
dc.identifier.doi10.1175/1520-0450(1979)018<1237:HEASSC>2.0.CO;2
dc.journal.fristpage1237
dc.journal.lastpage1239
dc.treeJournal of Applied Meteorology:;1979:;volume( 018 ):;issue: 009