| dc.contributor.author | Stull, Roland | |
| dc.date.accessioned | 2017-06-09T16:48:38Z | |
| dc.date.available | 2017-06-09T16:48:38Z | |
| dc.date.copyright | 2011/11/01 | |
| dc.date.issued | 2011 | |
| dc.identifier.issn | 1558-8424 | |
| dc.identifier.other | ams-74545.pdf | |
| dc.identifier.uri | http://onlinelibrary.yabesh.ir/handle/yetl/4216782 | |
| dc.description.abstract | n equation is presented for wet-bulb temperature as a function of air temperature and relative humidity at standard sea level pressure. It was found as an empirical fit using gene-expression programming. This equation is valid for relative humidities between 5% and 99% and for air temperatures between ?20° and 50°C, except for situations having both low humidity and cold temperature. Over the valid range, errors in wet-bulb temperature range from ?1° to +0.65°C, with mean absolute error of less than 0.3°C. | |
| dc.publisher | American Meteorological Society | |
| dc.title | Wet-Bulb Temperature from Relative Humidity and Air Temperature | |
| dc.type | Journal Paper | |
| dc.journal.volume | 50 | |
| dc.journal.issue | 11 | |
| dc.journal.title | Journal of Applied Meteorology and Climatology | |
| dc.identifier.doi | 10.1175/JAMC-D-11-0143.1 | |
| dc.journal.fristpage | 2267 | |
| dc.journal.lastpage | 2269 | |
| dc.tree | Journal of Applied Meteorology and Climatology:;2011:;volume( 050 ):;issue: 011 | |
| dc.contenttype | Fulltext | |