Show simple item record

dc.contributor.authorSpurr, G.
dc.date.accessioned2017-06-09T14:12:02Z
dc.date.available2017-06-09T14:12:02Z
dc.date.copyright1959/02/01
dc.date.issued1959
dc.identifier.issn0095-9634
dc.identifier.otherams-14490.pdf
dc.identifier.urihttp://onlinelibrary.yabesh.ir/handle/yetl/4150057
dc.description.abstractPower-station chimneys emit hot gases which may be sufficiently buoyant to penetrate inversions associated with periods of smog. Two notable instances of smog in Great Britain have been examined, applying formulae derived by Sutton and Priestley. A method has been suggested whereby an estimation may be made of the amount of heat required to ensure the penetration of an inversion by a plume.
dc.publisherAmerican Meteorological Society
dc.titleTHE PENETRATION OF ATMOSPHERIC INVERSIONS BY HOT PLUMES
dc.typeJournal Paper
dc.journal.volume16
dc.journal.issue1
dc.journal.titleJournal of Meteorology
dc.identifier.doi10.1175/1520-0469(1959)016<0030:TPOAIB>2.0.CO;2
dc.journal.fristpage30
dc.journal.lastpage37
dc.treeJournal of Meteorology:;1959:;volume( 016 ):;issue: 001
dc.contenttypeFulltext