Show simple item record

dc.contributor.authorHanna, Steven R.
dc.date.accessioned2017-06-09T14:01:24Z
dc.date.available2017-06-09T14:01:24Z
dc.date.copyright1986/10/01
dc.date.issued1986
dc.identifier.issn0733-3021
dc.identifier.otherams-11063.pdf
dc.identifier.urihttp://onlinelibrary.yabesh.ir/handle/yetl/4146250
dc.description.abstractHourly ground-level concentrations of SF6 at downwind distances ranging from 0.5 to 50 km were observed by the Electric Power Research Institute (EPRI) on dense monitoring networks around power plants at Kincaid, Illinois, and Bull Run, Tennessee. Sigma y on given sampling arcs was estimated by a robust procedure. Over 160 h of data are available from monitoring arcs located at about five downwind distances, which show that σy is close to linear with downwind distance, x. During unstable conditions, σyu/w*x=0.6. When all the data are plotted together, the following empirical equation is valid:
dc.publisherAmerican Meteorological Society
dc.titleLateral Dispersion from Tall Stacks
dc.typeJournal Paper
dc.journal.volume25
dc.journal.issue10
dc.journal.titleJournal of Climate and Applied Meteorology
dc.identifier.doi10.1175/1520-0450(1986)025<1426:LDFTS>2.0.CO;2
dc.journal.fristpage1426
dc.journal.lastpage1433
dc.treeJournal of Climate and Applied Meteorology:;1986:;Volume( 025 ):;Issue: 010