dc.description.abstractThe cooling capacity of an atmospheric environment is examined with respect to a wet object of a given surface temperature. The maximum cooling capacity (MCC) is defined as the sum of the sensible and latent heat fluxes out of a unit area of the object. The MCC can be used as a quantitative measure of the upper limit of the sum of some internal energy dissipation (total internal energy production minus mechanical work) and the absorbed radiant flux in a given object in thermal equilibrium. It is found that, for a given surface temperature and wind speed, the MCC is essentially a function of the wet bulb temperature of the ambient air with a very weak dependence on the ambient air temperature and pressure. It is further shown that the ambient temperature and pressure dependence can be ignored for practical purposes. A simple equation relating the MCC to surface temperature and ambient wet bulb temperature has been derived. Thus, in a given environment the wet bulb temperature sets a quantitative upper limit for the intensity of prolonged exercise.
dc.publisherAmerican Meteorological Society
dc.titleOn the Use of Wet Bulb Temperature as an Environmental Index
dc.typeJournal Paper
dc.journal.volume23
dc.journal.issue9
dc.journal.titleJournal of Climate and Applied Meteorology
dc.identifier.doi10.1175/1520-0450(1984)023<1387:OTUOWB>2.0.CO;2
dc.journal.fristpage1387
dc.journal.lastpage1391
dc.treeJournal of Climate and Applied Meteorology:;1984:;volume( 023 ):;issue: 009