| dc.description.abstract | The cooling capacity of an atmospheric environment is examined with respect to a wet object of a given surface temperature. The maximum cooling capacity (MCC) is defined as the sum of the sensible and latent heat fluxes out of a unit area of the object. The MCC can be used as a quantitative measure of the upper limit of the sum of some internal energy dissipation (total internal energy production minus mechanical work) and the absorbed radiant flux in a given object in thermal equilibrium. It is found that, for a given surface temperature and wind speed, the MCC is essentially a function of the wet bulb temperature of the ambient air with a very weak dependence on the ambient air temperature and pressure. It is further shown that the ambient temperature and pressure dependence can be ignored for practical purposes. A simple equation relating the MCC to surface temperature and ambient wet bulb temperature has been derived. Thus, in a given environment the wet bulb temperature sets a quantitative upper limit for the intensity of prolonged exercise. | |
| dc.publisher | American Meteorological Society | |
| dc.title | On the Use of Wet Bulb Temperature as an Environmental Index | |
| dc.type | Journal Paper | |
| dc.journal.volume | 23 | |
| dc.journal.issue | 9 | |
| dc.journal.title | Journal of Climate and Applied Meteorology | |
| dc.identifier.doi | 10.1175/1520-0450(1984)023<1387:OTUOWB>2.0.CO;2 | |
| dc.journal.fristpage | 1387 | |
| dc.journal.lastpage | 1391 | |
| dc.tree | Journal of Climate and Applied Meteorology:;1984:;volume( 023 ):;issue: 009 | |
| dc.contenttype | Fulltext | |