Show simple item record

dc.contributor.authorGregory A. Kopp
dc.contributor.authorJeong Hee Oh
dc.contributor.authorDiana R. Inculet
dc.date.accessioned2017-05-08T21:00:38Z
dc.date.available2017-05-08T21:00:38Z
dc.date.copyrightJuly 2008
dc.date.issued2008
dc.identifier.other%28asce%290733-9445%282008%29134%3A7%281129%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/35282
dc.description.abstractThe effects of ten different opening configurations on the internal pressures in a typical two-story North American house were examined using volume-scaled, wind tunnel experiments. The configurations examined include the effects of (1) dominant opening locations and sizes; (2) wall leakage; (3) compartmentalization of the attic space from the living space; and (4) roof and soffit vents. Helmholtz resonance was observed to significantly amplify the internal pressures for open area ratios greater than 3% and full-scale volumes of approximately
dc.publisherAmerican Society of Civil Engineers
dc.titleWind-Induced Internal Pressures in Houses
dc.typeJournal Paper
dc.journal.volume134
dc.journal.issue7
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)0733-9445(2008)134:7(1129)
dc.treeJournal of Structural Engineering:;2008:;Volume ( 134 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record