| dc.description.abstract | Although traditional mechanical dampers can help reduce cable vibrations, they are not the most effective solution due to their position restrictions. Tuned mass dampers (TMDs) were proposed to overcome this limitation and have been proven effective for cable vibration mitigation according to previous research. However, the effectiveness of TMDs is very sensitive to the vibration frequency, which implies that TMDs designed for a specific vibration frequency may not be efficient for other frequencies. A new type of mechanical damper named the TMD magnetorheological (MR) damper system is proposed in the present study to address this problem. The feature of this proposed damper is the combination of the position flexibility of TMDs and the adjustability of MR dampers. The proposed damper system is attached to a | |
| dc.publisher | American Society of Civil Engineers | |
| dc.title | Cable Vibration Control with a TMD-MR Damper System: Experimental Exploration | |
| dc.type | Journal Paper | |
| dc.journal.volume | 133 | |
| dc.journal.issue | 5 | |
| dc.journal.title | Journal of Structural Engineering | |
| dc.identifier.doi | 10.1061/(ASCE)0733-9445(2007)133:5(629) | |
| dc.tree | Journal of Structural Engineering:;2007:;Volume ( 133 ):;issue: 005 | |
| dc.contenttype | Fulltext | |